LI Zhengping1 XU Chao1 WU Ruisheng2 TAN Shoubiao1 1. Monte Carlo simulation of radiation dose distribution of γ-ray density meter[J]. Nuclear techniques, 2006, (3): 178-181.
LI Zhengping1 XU Chao1 WU Ruisheng2 TAN Shoubiao1 1. Monte Carlo simulation of radiation dose distribution of γ-ray density meter[J]. Nuclear techniques, 2006, (3): 178-181.DOI:
Monte Carlo simulation of radiation dose distribution of γ-ray density meter
we have calculated the radiation dose distribution near by a γ-ray density meter equipped in a 1600 type dredge ship
using Geant 4 (Monte Carlo simulation software). The most serious radiation leakage is found in the region close to the detector and it’s safe for using the γ-ray density meter under normal working condition. But under some abnormal condition such as the empty pipe
the density meter will detect a huge amount of radiation. For providing a safe circumstance
additional shield should be adopted. In fact a piece of steel plate of φ 50 cm ×7 cm in thickness could prevent most of escaping radiation and ensure the safety.