The high-purity nitric acid and hydrochloric acid were prepared by high-speed countercurrent chromatography(HSCCC)
using the 0.25 mol/L tri-octyl-phosphorous oxide in heptane as the stationary phase
and the normal nitric acid and hydrochloric acid were used as mobile phase. The results show that the uranium contained in the acid purified is reduced to lower than 1 pg/mL
which is close to the content of uranium in the high-purity water and the high-purity acid prepared by isothermal evaporation and sub-boil distillation.