WANG Liwei GU Ming YUAN Qibing. Data acquisition and processing in stability control system of LINAC modulator[J]. Nuclear techniques, 2012, 35(7): 543-548.
WANG Liwei GU Ming YUAN Qibing. Data acquisition and processing in stability control system of LINAC modulator[J]. Nuclear techniques, 2012, 35(7): 543-548.DOI:
Data acquisition and processing in stability control system of LINAC modulator
介绍了相关的实验测试和信号处理方法。数据采集系统由Stratix ii FPGA开发板、AD6645、上位PC机组成
借用差分放大器提高测量分辨率。数据处理采用脉冲采样样本均值作为表征幅度的特征量
并采用平均、插值、数字滤波、BP神经网络等方法来提高幅度监测值的分辨率能力和抗干扰能力。
Abstract
In this paper
we report the design of data acquisition(DAQ) and processing(DSP) system for feedback control of a linac modulator to improve amplitude stability of its output HV pulse.Hardware and software requirements for the system are analyzed to achieve the required stability
and relevant experimental results are given..The DAQ system consists of stratix ii FPGA board
AD6645 and upper PC.The measurement resolution is improved by use of differential amplifier.DSP algorithm takes sample mean value as pulse amplitude.Methods of average
interpolation
digital filtering