HUANG Guoqing CHEN Jie CHEN Zhichu LENG Yongbin YE Kairong. X-ray pinhole camera control system design for SSRF storage ring[J]. Nuclear techniques, 2011, 34(9): 641-645.
HUANG Guoqing CHEN Jie CHEN Zhichu LENG Yongbin YE Kairong. X-ray pinhole camera control system design for SSRF storage ring[J]. Nuclear techniques, 2011, 34(9): 641-645.DOI:
X-ray pinhole camera control system design for SSRF storage ring
Beam emittance is an important parameter for a third-generation synchrotron light source.In this paper
we report design of the control system of the X-ray pinhole camera to measure emittance of SSRF.The PXI-7344 controls the attenuator motion
the PXI-8252 collects the X-ray image by IEEE1394
and the RS232 controls four-dimensional motion of the pinhole and two-dimensional motion of the camera.The software was developed on LabVIEW platform to communicate with the accelerator control system via EPICS Shared Memory IOC core interface.Since August 2009
the X-ray pinhole camera system has been working reliably in measuring the beam emittance of just 3.9 nm.rad.