The measurement of central and fringe field of the Moblеу magnet for compressing beam pulse and the improvement of the uniformity
|更新时间:2022-09-13
|
The measurement of central and fringe field of the Moblеу magnet for compressing beam pulse and the improvement of the uniformity
Nuclear TechniquesVol. 09, Issue 12, (1986)
作者机构:
四川大学原子核科学技术研究所
作者简介:
基金信息:
DOI:
CLC:
Received:21 March 1985,
Published:1986-12
稿件说明:
移动端阅览
Weidong Shi. The measurement of central and fringe field of the Moblеу magnet for compressing beam pulse and the improvement of the uniformity[J]. Nuclear techniques, 1986, 09(12): 27-31,56.
DOI:
Weidong Shi. The measurement of central and fringe field of the Moblеу magnet for compressing beam pulse and the improvement of the uniformity[J]. Nuclear techniques, 1986, 09(12): 27-31,56.DOI:
The measurement of central and fringe field of the Moblеу magnet for compressing beam pulse and the improvement of the uniformity
The central and fringe field of a Mobley magnet were measured using nuclear magnetic resonance and Hall voltage differences method. The field uniformity can be raised from ±7×10
-4
to ±3×10
-4
by adjusting the thickness of spacers between magnetic poles. The effects of the place
thickness
width of the magnetic screen on Mobley magnet fringe field have been observed. The errors between the results of two method are analysed and the accuracy is given.