浏览全部资源
扫码关注微信
1.中国科学院高能物理所
2.中国原子能研究院
Received:10 April 1989,
Published:1990-08
移动端阅览
Min Tan, Changmao Chen, Zheng Wang, et al. Study on geomelrical response of Leake counters[J]. Nuclear techniques, 1990, 13(8): 460-462.
研究了不同吸收层结构的Leake计数器的角响应和径向微分响应。结果表明,这些响应与吸收层结构基本无关。并且径向微分响应可用公式
http://html.publish.founderss.cn/rc-pub/api/common/picture?pictureId=34178121&type=
http://html.publish.founderss.cn/rc-pub/api/common/picture?pictureId=34178123&type=
http://html.publish.founderss.cn/rc-pub/api/common/picture?pictureId=34178122&type=
拟合。
Leake counters are commonly used in neutron dose-equivalent rate measnrement. In this paper
the directionality and collimated beam response of Leake counters are described. The experimental results show that there is no directional dependence for Leake counters
and that Leake counters with different absorbers have similar collimated beam respouse
which can be expressed by the formula
http://html.publish.founderss.cn/rc-pub/api/common/picture?pictureId=34178124&type=
http://html.publish.founderss.cn/rc-pub/api/common/picture?pictureId=34178126&type=
http://html.publish.founderss.cn/rc-pub/api/common/picture?pictureId=34178125&type=
.
陈常茂 等 , 辐射防护 , 6 ( 1986 ) 5 : 344 .
陈常茂 等 , 原子核物理 , 9 ( 1987 ), 360 .
C. A. Perks , Rad. Pro. Dos. , 15 ( 1986 ), 31 .
0
Views
20
下载量
0
CSCD
Publicity Resources
Related Articles
Related Author
Related Institution
京公网安备11010802024621