Correction functions for the efficiency calibration of Gamma-ray spectra analysis used for cylindric samples with different height
|更新时间:2022-08-16
|
Correction functions for the efficiency calibration of Gamma-ray spectra analysis used for cylindric samples with different height
Nuclear TechniquesVol. 12, Issue 2, (1989)
作者机构:
卫生部工业卫生实验所
作者简介:
基金信息:
DOI:
CLC:
Received:08 June 1987,
Published:1989-02
稿件说明:
移动端阅览
Qiong Su, Yamin Gao. Correction functions for the efficiency calibration of Gamma-ray spectra analysis used for cylindric samples with different height[J]. Nuclear techniques, 1989, 12(2): 65-69.
DOI:
Qiong Su, Yamin Gao. Correction functions for the efficiency calibration of Gamma-ray spectra analysis used for cylindric samples with different height[J]. Nuclear techniques, 1989, 12(2): 65-69.DOI:
Correction functions for the efficiency calibration of Gamma-ray spectra analysis used for cylindric samples with different height
A mathematical model is given to describe the relation between the efficiency function of quantitative analysis for gamma-ray spectra and height of samples
which are put into a certain cylindric container. It not only simplifies the effeciency calibration of samples
but facilitates the data processing by computers automatically also.