The three gradient method for determination of beam emittance was described. The SEM multiwire devices set behind quadrupole or a pair of quadrupole magnets have been applied to measure the beam emittance. For obtaining better results the measured data were disposed mathematically with least square method. A computer program was written to obtain and display the beam emittance
related parameters as well as the beam ellipse. The beam emittance in both horizontal and vertical plane can be determined at same time by this method. The factors affecting the precision of measured results were discussed briefly in the paper.
关键词
Keywords
references
K. Ishii et al. , Nuclear Instr. Meth. , 185 ., 1 ( 1981 ).
P. Strehl et al. , IEEE Tran. Nucl. Sci. , NS-28 , 3 , 2216 ( 1981 ).
E. R. Gray , ibid , NS-18 , 3 , 941 ( 1971 ).
G. Baribaud and C. Metzger , ibid , NS-20 , 3 , 659 ( 1973 ).
R. Anne and M. Van den Bossche , ibid , NS-26 , 2 , 2379 ( 1979 ).