用铥(或镝)激活的硫酸钙——CaSO
4
:Tm(或镝)热释光剂量计(简称TLD)在γ射线的低能范围(
<
200keV)有较大的能量响应,是一种制备和实用都很方便的磷光体,但要用它测量β射线的吸收剂量,必须将其制成厚约20μm左右的超薄元件。我们用CaSO
4
:Tm测定γ和X射线的剂量以后,就着手于超薄型元件的制作,并对它的应用也做出了初步探讨。元件的制作是将粒度1~8μm的CaSO
4
:Tm粒末均匀地沉积在银托片上,然后加粘结剂烧结而成。这种元件经反复使用不会脱落,它可用于测定
β
照射的吸收剂量。
This paper describes the preparation of the ultrathin TLD (thermoluminescent detector) element by depositing CaSO
4
:Tm onto a silver disc. The method described includes the chosing of 1~8µm CaSO
4
:Tm grains and the shaping sintering of 5~10µm CaSO
4
:Tm samples. Some of the dosimetry properties of the TLD element are given too. And a method of using the element to measure the dose absorbed by a matter irradiated by
β
-rays is proposed.
Finally
some problems found in application are discussed. The conclusion is that according to the exposure of γ-rays
the TLD element can be used to measure relatively the dose absorbed by a matter irradiated by
β
-rays of an average energy between 0.2 and 0.9 MeV with deviation of ±10%.
U. Greitz and B. I. Ruděn , Phys. Med. Biol ., 17 , 193 ( 1972 ).